Equipped with 8 fluorescent UV lamps (40 W each), the device delivers stable spectral power distribution that does not degrade significantly even after 5,000 hours of continuous operation. The irradiation intensity is adjustable from 0.3–20 W/m², while the temperature range spans ambient to 90°C ±2°C. A programmable water spray system further allows simulation of rainfall or moisture exposure, ensuring realistic environmental stress for plastics, coatings, textiles, electronics, paints, automotive parts, and other UV-sensitive materials.Achieve up to 10x faster material aging than natural sunlight, dramatically shortening product development cyclesIntegrated sensors and radiometers monitor lamp intensity, black panel temperature, chamber humidity, and environmental parameters in real time.
Key Advantages That Set This UVA UVB UVC Lamp Degradation Test Device Apart
Full-Spectrum UV Simulation – Simultaneously tests UVA, UVB, and UVC effects, providing a comprehensive view of material responses to different UV wavelengths and energy levels.
Precision Environmental Control – Maintain temperature with ±2°C accuracy, humidity up to ≥95% RH, and irradiation intensity of 0.3–20 W/m², ensuring scientifically valid, repeatable results.
Robust and Durable Design – The SUS304 stainless steel interior resists corrosion from UV exposure and moisture, while the exterior steel panels with protective coating provide structural stability and longevity.
Smart Monitoring & Automation – Advanced PLC touchscreen interface supports programmable cycles, real-time feedback, automated alarms, and USB or Ethernet data export, reducing human error and streamlining long-term testing workflows.
Integrated Moisture & Rain Simulation – Water spray system and humidity control recreate realistic environmental stresses, such as rain, dew, and condensation effects on materials.
Black Panel Temperature Feedback – Black panel sensor ensures surface temperature accuracy, replicating real-world thermal impact on UV-sensitive materials.
Automated Lamp Health Monitoring – Built-in radiometer detects lamp aging or failure in real time, ensuring consistent UV output throughout testing cycles.
What Are the Technical Specifications You Need to Know?
|
Model |
UV-SI-260 |
|||
|
Internal Dimension (mM) |
450*1170*500 |
|||
|
Overall Dimension (mM) |
610*1330*1470 |
|||
|
Specimen Holder Size(mm) |
75*150 |
|||
|
Specimen Capacity |
56pcs |
|||
|
Irradiation Source |
Fluorescent UV lamps (8) - 40 W |
|||
Irradiance control |
0.3~20 W/㎡ |
|||
Bandwidth |
290 ~ 400nm |
|||
|
Temperature Range |
Ambient ~ 90 ℃ ±2℃ |
|||
|
Black Panel Temperature (BPT) |
35 ~ 80 ℃ |
|||
|
Humidity Range |
≥95% RH | |||
|
Water Spray Cycle |
1~9999H59M (Adjustable) |
|||
|
Water supply system |
Automatic water supply, Water purification system |
|||
|
Distance of Specimen and lamp |
50mm |
|||
|
Controller |
Programmable color LCD touch screen controller, Ethernet connectio |
|||
|
Safety Device |
Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection; Phase Sequence Protection |
|||
|
Interior Material |
SUS304 stainless steel |
|||
Highlights of UVA UVB UVC Lamp Degradation Test Device
Independent UVA, UVB, UVC Lamps
Each lamp is independently adjustable for intensity and exposure duration, allowing highly customizable and repeatable test scenarios.
Extended continuous operation up to 5,000 hours, Each UV lamp tube has its own independent current display.
8 pcs 40W of UV lamp are installed in workroom.

Advanced Sample Holder System
Standard aluminum racks hold up to 56 specimens (75×150 mm), ensuring uniform UV exposure across all samples. Custom holders are available for profile-shaped, tubular, or irregular materials.

Programmable Touchscreen Controller
Multi-cycle programming enables temperature ramping, irradiation timing, water spray cycles (1–9999H59M adjustable), and real-time monitoring.
USB and Ethernet connectivity allows automated reporting and remote supervision.

Radiometer for Irradiance Monitoring
Continuously measures UV lamp output to detect lamp aging or failure, ensuring consistent irradiation intensity and valid test results.

Water Spray & Humidity System
Automatic water supply with purification system enables intermittent or continuous spray cycles, simulating rain, condensation, or moisture effects on materials.

Understanding UVA UVB UVC Lamp Testing for Accurate Material Aging
1. What are the differences between UVA, UVB, and UVC lamps?
2. Can light exposure and condensation cycles switch automatically?
3. How is consistent light intensity maintained during testing?
Take Action: Enhance Material Durability with Confidence
Accelerate your R&D and QA processes with the UVA UVB UVC Lamp Degradation Test Device.
Contact LIB industry today sales@libtestchamber.com to request a demonstration, consult on custom configurations, or obtain detailed specifications within 1–3 hours.
Fast Delivery | Custom Configurations | 3-Year Warranty & Lifetime Technical Support.
Hot Tags: uva uvb uvc lamp degradation test device, uva uvb uvc lamp degradation test device manufacturers, suppliers, factory, xenon arc chamber, xenon tester, Solar Radiation UV Accelerated Weathering Tester, xenon lamp aging tester, xenon lamp aging test chamber, UV Weather Resistance Test Chamber