Engineered for high-fidelity sunlight reproduction, the G151 xenon arc weathering test apparatus delivers laboratory-grade acceleration for UV, visible, and IR aging.
Sample holder:Adjustable speed, 1r/min
Irradiance Range: 30-150W/㎡
Bandwidth Measurement:300~400nm;320nm;420nm
Black Panel Temperature: 35 ~ 85 ℃ ;
Humidity Range30% ~ 98% RH;
Standard Models: XL-S-750, XL-S-500 (more custom dimensions available)
Standards Compliance: ASTM G151, ASTM G155, ISO 4892-2, ISO 105-B02/B04, AATCC TM16, IEC 60068-2-5, SAE J2020
Category
Xenon Chamber
Share to
Description

Its 4500 W water-cooled xenon lamp maintains 35–150 W/m² stable irradiance with ±0.5% precision, ensuring repeatable exposure across long test cycles. The controlled environment supports BPT 35–85 °C, air temperature ambient100 °C, and 5098%RH humidity, enabling complex degradation of polymers, coatings, automotive trims, and outdoor materials.

A redesigned system architecture integrates window/daylight/extended-UV filters, programmable wet–dry and spray cycles, and a smart PID touchscreen controller with multi-language UI, remote monitoring, and full data export.

Purpose-built for G151-compliant weathering, it helps manufacturers predict color fade, cracking, gloss loss, and mechanical decay with fast, traceable results.

 

 

Key Advantages of LIB Industry G151 Xenon Arc Weathering Test Apparatus

 

1

True Solar Replication for Fast, Realistic Aging
Its full-spectrum UV–VIS–IR output recreates outdoor sunlight with laboratory stability, combined with ambient–100 °C thermal loading and a built-in condensation cycle that simulates dawn moisture and surface cooling. A long-life xenon lamp (>1600 h) ensures consistent exposure throughout extended test programs.

2

High-Precision Exposure Reliability
A redesigned optical layout ensures exceptional irradiance uniformity across every test zone, while synchronized control of spectrum, temperature, and humidity stabilizes long-duration weathering. Cross-chamber repeatability remains tight, delivering certification-ready data for quality comparison and production validation.

3

Wide Material Compatibility for G151 Weathering
The system targets real-world degradation of automotive interiors/exteriors, outdoor plastics and polymers, photovoltaic materials, coated metal panels, construction materials, and packaging inks-covering the full spectrum of UV/visible aging, gloss loss, and structural decay required by G151 workflows.

4

Flexible Architecture for Complex Test Demands
Engineered for scalability, it supports expanded sample capacity, adjustable spray pressure and nozzle configurations, and tailored spectral emphasis in UV or IR ranges to match product-specific failure modes.

 

 

 

What Are the Technical Specifications You Need to Know?

Model

XL-S-750

XL-S-500

Internal Dimension (mM)

950*950*850 mm

500*600*700 mm

Overall Dimension (mM)

1400*1400*1950 mm

1000*1140*1920 mm

Specimen Holder Size(mm)

95*200

/

Specimen Capacity

42pcs

/

Chamber Type

Rotating Holder

Flat shelf

Irradiation Source

1 piece of 4500w water-cooled xenon arc lamp

Irradiance Range

35~150 W/㎡

Bandwidth Measurement

300nm~400nm (340nm or 420nm)

Chamber Temperature Range

Ambient ~ 100 ℃ ±2℃

Black Panel Temperature

BPT 35 ~ 85 ℃ ±2℃

Humidity Range

50% ~ 98% RH

Humidity Deviation

± 5% RH

Water Spray Cycle

1~9999H59M (Adjustable)

Water supply system

Automatic water supply, Water purification system

Radiometer

UV Radiometer, Tolerance: ±5%

Cooling System Mechanical compression refrigeration system
 

Engineering Highlights – G151 Xenon Arc Weathering Test Apparatus

Xenon Lamp

Type: High-intensity xenon arc lamp, full-spectrum UV–VIS–IR

Power: 4500 W water-cooled system

Irradiance Range: 35–150 W/m² with ±0.5 % stability

Lamp Life: ≥1600 hours; easily replaceable with standardized mounting

Optional: Extended UV or IR emphasis for accelerated degradation testing

G151 Xenon Arc Weathering Test Apparatus4

 

 

 

Workroom

Material: SUS304 stainless steel, corrosion-resistant and durable

Temperature Range: Ambient–100 °C with ±0.5 °C stability

Design: Optimized internal airflow to prevent hot/cold spots and condensation; reflective interior surfaces enhance uniform light distribution

G151 Xenon Arc Weathering Test Apparatus8

Specimen Holder

Holder Size: 95 × 200 mm (customizable based on sample size)

Specimen Capacity: Standard 42 pcs, expandable with optional racks

Type: Rotating holder for uniform exposure of all samples

Features: Adjustable rotation speed ensures even irradiance; optional multi-tier holders to accommodate larger test loads

G151 Xenon Arc Weathering Test Apparatus6

Controller

Interface: Color touchscreen with programmable test cycles

Remote Functionality: Supports remote control, monitoring, alarms, and real-time data logging

Data Management: Automatic export via USB or Ethernet; backend storage of experiment logs for traceability

Advanced Features: Multi-language support, programmable wet–dry cycles, lamp irradiance scheduling

G151 Xenon Arc Weathering Test Apparatus5

Irradiance Meter

Function: Real-time measurement of irradiance to maintain uniform exposure

Wavelength Range: Standard 340 nm and 420 nm; multiple sensors can be installed simultaneously

Integration: Automated feedback to controller for lamp adjustment, ensuring compliance with ASTM G151/G155 standards

Optional: Data logging and calibration alerts for quality control

G151 Xenon Arc Weathering Test Apparatus7

 

Discover ASTM G151 Xenon Arc Weathering Test Apparatus

 

 

1. Is this equipment suitable for evaluating long-term coating durability?

Yes. LIB industry builds the G151 apparatus specifically for coatings, automotive paints, powder coatings, and UV-cured layers. For corrosion-related studies, LIB industry can additionally provide salt spray chambers for combined aging workflows.

2. Can the apparatus test temperature-sensitive or oversized samples?

Yes. Flexible sample frames and optional extended-height workrooms allow unusual geometries and low-mass materials to be exposed without overheating.

3. How often are filters and lamps serviced?

Optical filters should be checked and cleaned every 3–6 months, while xenon lamps usually require replacement after 1600 hours depending on irradiance level.

 

Accelerate Weathering Data with Confidence – Choose LIB Industry

The G151 Xenon Arc Weathering Test Apparatus gives laboratories the ability to produce predictable, repeatable, and quantifiable weathering results, reducing outdoor exposure time and eliminating environmental uncertainty.

Why laboratories choose LIB industry

  • Customizable workroom volume, optical filters, and irradiance windows
  • Compliance with ASTM, ISO, AATCC, and IEC standards
  • Water-cooled xenon technology for superior stability
  • 3-year warranty + lifetime technical support
  • Proven engineering for long, unattended operation

Start Your ASTM G151 Project Today

Contact LIB industry → sales@libtestchamber.com

Hot Tags: g151 xenon arc weathering testing apparatus, g151 xenon arc weathering testing apparatus manufacturers, suppliers, factory, xenon lamp aging test chamber, Xenon Weatherometer, UV Weather Resistance Test Chamber, xenon weathering test, xenon arc aging test chamber, Xenon Weathering Test Chamber

Send Inquiry