Designed for precision and repeatability, it exposes metals, coatings, and components to sulfur dioxide (SO2), hydrogen sulfide (H2S), nitrogen dioxide (NO2), and chlorine (Cl2) gases under controlled temperature, humidity, and concentration conditions. This equipment provides accelerated corrosion testing to identify vulnerabilities in materials and ensure product durability under extreme toxic gas environments.Designed to comply with international standards such as ASTM G85, ISO 3231.
Engineered to precisely replicate industrial and natural gas-corrosive conditions, it supports long-duration tests and multi-step programmable cycles for predictive analysis of material and coating performance. Its advanced control system ensures uniform gas distribution, stable temperature and humidity, and safe operation even under toxic gas exposure.
Key Advantages of SO2 / H2S / NO2 / Cl2 Toxic Gas Corrosion Test Equipment
Precise Multi-Gas Control
- Supports SO2, H2S, NO2, and Cl2 individually or in combination.
- Gas concentrations adjustable from 1–500 ppm for accelerated or mild corrosion testing.
Environmental Parameters Stability
- Accurately controls temperature (+10 ℃ ~ +90 ℃), humidity (30%–98% RH), and gas exposure cycles.
- Supports continuous, cyclic, and programmable multi-step test profiles.
Safe, Durable, and Chemical-Resistant Construction
- Integrated SUS 316body resists corrosion by toxic gases, ensures long-term durability, and reduces maintenance.
- Optional fume extraction and ventilation systems protect operators during long tests.
Advanced Control System
- 7-inch touchscreen with intuitive interface.
- Multi-step programmable profiles for temperature, humidity, and gas concentration.
- Real-time monitoring, data logging, and Ethernet/USB remote control.
Tailored to Your Needs
– Choose from standard models or fully customized solutions, including walk-in sizes for large or multiple samples.
Ultimate Gas Flexibility
– Test with a single gas or combine multiple gases to replicate real-world industrial and urban atmospheres.
Reliable, Repeatable Results
– Advanced air circulation ensures uniform exposure and stable conditions, giving you trustworthy, actionable data every time.
What Are the Technical Specifications You Need to Know?
|
Model |
GCM-100 |
GCM-225 | GCM-500 | |
|
Internal Dimension (mm) |
400*500*500 |
500*600*750 |
700*800*900 | |
|
Overall Dimension (mm) |
1010*1050*1620 |
1110*1150*1860 |
1330*1350*2010 | |
|
Interior Volume |
100L |
225L | 500L | |
|
Temperature Range |
15 ℃ ~ 80 ℃ |
|||
|
Temperature Fluctuation |
± 0.5 ℃ |
|||
|
Temperature Deviation |
± 2.0 ℃ |
|||
|
Cooling system |
Mechanical compression refrigeration system |
|||
Humidity Range |
30% ~ 98% RH |
|||
| Humidity Deviation | ± 2.5% RH | |||
SO2 Concentration |
100 ~500 ppb± 20 ppb (Adjustable) |
|||
H2S Concentration |
10 ~100 ppb ± 20 ppb (Adjustable) |
|||
NO2 Concentration |
200 ppb ± 20 ppb (Adjustable) |
|||
| Cl2 Concentration | 10 ~20 ppb ±5 ppb (Adjustable) | |||
Air Change Rate |
3~10times /h |
|||
Water Supply System |
Water purification system, Automatic water supply |
|||
Controller |
Programmable color LCD touch screen controller Ethernet connection, PC Link |
|||
Gas Sensor |
H2S/NO2/CL2/SO2 gas sensor |
|||
Door Lock |
Electromagnetic lock |
|||
Gas Exhaust Device |
Exhaust Unit |
|||
Safety Device |
Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection; Water Shortage Protection; Earth leakage Protection |
|||
| Interior material | SUS316 stainless steel +Glass fiber reinforced plastics | |||
Design Highlights of SO2 / H2S / NO2 / Cl2 Toxic Gas Corrosion Test Equipment
SUS 316 stainless steel, the workroom resists temperature, moisture, and corrosive gas exposure.
Its concave–convex structure with double-layer silicone sealing strips ensure airtight performance. Equipped with a electromagnetic safety lock, preventing accidental openings.
A frost-free observation window with built-in LED lighting allows clear monitoring.
Adjustable, removable stainless steel sample shelves accommodate various test sizes.

Independent Flowmeters & Gas Probes – Precision Control

Each toxic gas line features an independent flowmeter and dedicated concentration probe, allowing precise single-gas or multi-gas operation. Control accuracy: ±1% F.S., ensuring reproducible and reliable testing.
Color touchscreen PID controller supports 120 programs with 100 segments, enabling complex automated test cycles. Programs can be preset according to customer requirements. Multi-language interface improves usability across global applications.

Advanced Air Circulation System – Uniform & Stable Environment

High-efficiency internal circulation ensures even gas distribution and maintains temperature/humidity stability (±0.5°C / ±2% RH) throughout the chamber, delivering accurate and repeatable corrosion test results.
Equipped with an automatic NaOH neutralization tank, toxic gases (SO2, H2S, NO2, Cl2) are safely diluted before discharge. Fully controlled via the system, it protects the laboratory environment and ensures operator safety.

Frequently Asked Questions on SO2 / H2S / NO2 / Cl2 Toxic Gas Corrosion Testing
1️⃣ Which gases can be tested?
2️⃣ How is gas concentration controlled?
3️⃣ How is operator safety ensured with toxic gases?
Ensure Material Durability Under Harsh Toxic Gas Environments
Accelerate product development, validate coatings, and guarantee compliance with industrial and environmental corrosion standards. Contact LIB industry today at sales@libtestchamber.com to customize your SO2 / H2S / NO2 / Cl2 Toxic Gas Corrosion Test Equipment. Receive a tailored solution and quotation within 1–3 hours.
Fast Delivery | Custom Configurations | 3-Year Warranty & Lifetime Technical Support.
Hot Tags: so2 / h2s / no2 / cl2 toxic gas corrosion test equipment, so2 / h2s / no2 / cl2 toxic gas corrosion test equipment manufacturers, suppliers, factory, Ozone Aging Test Machine, Rubber Ozone Aging Test Chamber, Mixed Gas Corrosion Chamber, Ozone Climatic Chamber, H S Corrosive Gas Test Chamber, SO2 Corrosion Test Chamber