Equipped with a PID-controlled dual-stage refrigeration system and high-accuracy platinum resistance temperature sensors (PT100Ω, Class A), the chamber achieves steady-state equilibrium within minutes and maintains temperature drift below 0.1°C/hour. Standard volumes from 100L to 1000L provide flexibility for both small-scale sensor verification and large-scale multi-instrument calibration setups.
Unlike conventional environmental chambers, LIB Industry's Environmental Temperature Calibration Chamber models are specifically tuned for temperature uniformity, stability, and low thermal gradient performance, making them ideal for ISO/IEC 17025-compliant calibration laboratories and industries requiring traceable calibration accuracy down to ±0.05°C resolution.
Why Use an Environmental Temperature Calibration Chamber?
Calibration is the foundation of accurate measurement and quality assurance. The temperature calibration chamber enables:
Sensor Accuracy Verification:
Quickly and precisely identify deviations across full operating temperature ranges.
Controller and Instrument Validation:
Test thermostats, data loggers, IC sensors, and industrial controllers under controlled thermal conditions.
Traceable Standards Compliance:
Ensure calibration aligns with IEC, ASTM, MIL-STD, and ISO/IEC 17025 requirements.
Accelerated Device Assessment:
Simulate long-term temperature exposure in hours, verifying performance stability over time.
By reproducing stable and repeatable environmental conditions, LIB Industry Environmental Temperature Calibration Chamber minimize error margins, ensuring devices perform reliably in production, field, or research environments.
Key Advantages of LIB Industry Environmental Temperature Calibration Chamber
High-Precision Temperature Control
Advanced PID control with high-resolution PTR platinum resistance sensors (PT100Ω, Class A) maintains ±0.2°C stability, critical for laboratory-grade calibration.
Wide Temperature Range & Configurability
Supports –70°C to +150°C, with multiple selectable temperature ranges to meet various sensor and instrument calibration needs.
Exceptional Uniformity
Optimized multi-directional airflow and axial fan circulation maintain ±0.5°C uniformity, ensuring all devices experience identical conditions.
Flexible Sample Accommodation
Internal volumes from 100L to 1000L with adjustable SUS304 stainless steel shelves, supporting simultaneous calibration of multiple sensors or large instrumentation assemblies.
Enhanced Safety & Accessibility
Observation window with LED lighting, Ø50mm cable ports for sensor connections, automatic defrosting, over-temperature protection, and compressor overload alarms ensure safe and uninterrupted operation.
What Are the Technical Specifications You Need to Know?
|
Model |
T-100 |
T-225 |
T-500 |
T-1000 |
|
Internal Dimension (mm) |
400*500*500 |
500*600*750 |
700*800*900 |
1000*1000*1000 |
|
Overall Dimension (mm) |
900*1050*1620 |
1000*1140*1870 |
1200*1340*2020 |
1500*1540*2140 |
|
Interior Volume |
100L |
225L |
500L |
1000L |
|
Heat load |
1000W |
|||
|
Temperature Range |
A : -20℃ ~ +150 ℃ B : -40℃ ~ +150 ℃ C: -70℃ ~ +150 ℃ |
|||
|
Temperature Fluctuation |
± 0.5 ℃ |
|||
|
Temperature Deviation |
± 2.0 ℃ |
|||
|
Humidity Range |
20% ~ 98% RH |
|||
|
Humidity Deviation |
± 2.5% RH |
|||
|
Cooling Rate |
1 ℃ / min |
|||
|
Heating Rate |
3 ℃ / min |
|||
|
Controller |
Programmable color LCD touch screen controller,PC Link, LAN interface | |||
|
Temperature Sensor |
PTR Platinum Resistance PT100Ω/MV A-class | |||
|
Cooling system |
Mechanical compression refrigeration system,environmentally friendly refrigerant. | |||
|
Refrigerating unit |
French TECUMSEH compressor | |||
|
Water supply system |
Automatic water supply; Water purification system | |||
Highlights of Controlled Temperature Chamber for Automotive

Stainless-Steel Workspace with Integrated Sensors
The inner workspace is made of SUS#304 stainless steel, ensuring durability and thermal consistency. Built-in PT100 temperature probes (±0.1°C) and digital humidity sensors (±1.5%RH) monitor real-time conditions, while the 360° air circulation system maintains uniform temperature (≤0.5°C deviation) for accurate multi-point calibration.
Airtight Sealing and Thermal Insulation
The temperature calibration chamber uses a multi-layer silicone gasket and high-density polyurethane insulation to achieve exceptional sealing and temperature stability. Door latches ensure leakage below 1.5% per hour, and a heated double-glass window prevents condensation for clear visibility during operation.


Reliable Cascade Refrigeration System
Dual-stage compressors (French TECUMSEH) with environmentally friendly refrigerants provide rapid cooling, minimal overshoot, and stable long-term operation for continuous calibration tasks.
User-Friendly Interface & Data Logging
Color LCD touch controller allows up to 120 programmable steps, real-time temperature graphing, USB data logging, LAN and PC-link connectivity for remote monitoring, and full traceability for compliance audits.

Environmental Temperature Calibration Chamber – Expert Q&A
Can multiple sensors be calibrated simultaneously?
Yes. Adjustable stainless steel shelves allow simultaneous calibration while maintaining uniform temperature distribution.
Does the environmental temperature calibration chamber support remote monitoring?
Absolutely. USB, LAN, and PC-link connectivity enable remote operation, monitoring, and traceable data logging.
Can it be customized for specialized calibration requirements?
Yes. LIB Industry provides custom volumes, temperature ranges, and water-cooled options for high-power or continuous calibration applications.
How does it maintain high precision at extreme temperatures?
The combination of PTR Class A sensors, high-efficiency dual-stage cascade refrigeration, and precise PID control ensures ±0.2°C stability across the full range.
Start Your High-Precision Calibration Today
Ensure every sensor, instrument, and control system operates with maximum accuracy using LIB Industry's Environmental Temperature Calibration Chamber. Reduce calibration errors, enhance device reliability, and comply with international standards.
Contact LIB Industry now at info@libclimatetest.com - receive a tailored solution and quotation within 1–3 hours, and begin precise calibration with confidence and global compliance.
Hot Tags: environmental temperature calibration chamber, environmental temperature calibration chamber manufacturers, suppliers, factory, Humidity environment test chamber, Humidity test cabinet, Humidity test chamber for sale, Temperature and humidity stability test chamber, Test chamber humidity, Thermal humidity test chamber